MightyPure™ Standard Model Germicidal Lamp Data
STER-L-RAY™ germicidal lamps are shortwave, low pressure mercury vapor
discharge tubes that produce ultraviolet wavelengths lethal to microorganisms.
TO ORDER SELECT THE LAMP NUMBER FOR YOUR MODEL PURIFIER
|
| Lamp No. |
Model No. |
Nominal Lamp Length |
Power Consumption [Watts]
(1) |
UV Output [Watts] (2) |
Rated Effective Life [Hrs.] |
 |
| 05-1400 |
MP13A/B/C |
8-15/16"
(227mm) |
10 |
2.3 |
10,000 |
| 05-1098 |
MP16A/B/C |
11-7/8"
(302mm) |
14 |
3.7 |
10,000 |
| 05-1097 |
MP22A/B/C |
17-3/4"
(451mm) |
20 |
6.4 |
10,0000 |
| 05-1116 |
MP36 |
31 1/4" |
38 |
13.8 |
10,000 |
|
|
(793mm) |
|
|
|
| 05-1343 |
MP36A/B/C |
33-7/8"
(860mm) |
39 |
13.8 |
10,000 |
| 05-1334 |
MP49A/B/C |
45-7/8"
(1165mm) |
50 |
19.3 |
10,000 |
(1) Wattage is lamp watts only and does not include ballast loss (approximate).
(2) Maximum rated output at 254 nanometers.
The lamps listed above have been especially developed and are recommended for use with MightyPure™ Water Purifiers. All STER-L-RAY™ lamps used in MightyPure™ units are low pressure type which afford the maximum efficiency in producing the required germicidal rays. In addition to the obvious advantages of high efficiency and low power requirements, there is no possibility of the unit overheating (as is the case with some other lamp types). Consequently, the need for additional equipment to combat overheating is eliminated.
CAUTION: Exposure to direct or reflected germicidal ultraviolet rays will cause painful eye irritation and reddening of the skin. Personnel subject to such exposure must wear suitable face shield, gloves and protective clothing. Hg - LAMP CONTAINS MERCURY, manage in accord with disposal laws, see: http://www.lamprecycle.org/.
|
Minipure® Lamp Data
STER-L-RAY™ germicidal lamps are shortwave, low pressure mercury vapor
discharge tubes that produce ultraviolet wavelengths lethal to microorganisms.
TO ORDER SELECT THE LAMP NUMBER FOR YOUR MODEL PURIFIER
|
| Lamp No. |
Model No. |
Nominal Lamp Length |
Power Consumption [Watts]
(1) |
UV Output [Watts] (2) |
Rated Effective Life [Hrs.] |
 |
| 05-1119 |
MIN-1A/B/C |
8-11/32"
(212mm) |
10 |
2.3 |
10,000 |
| 05-1366 |
MIN-1.5A/B/C |
11-19/64"
(287mm) |
14 |
3.7 |
10,000 |
| 05-1366 |
MIN-3A/B/C |
11-19/64"
(287mm) |
14 |
3.7 |
10,000 |
| 05-1370 |
MIN-6A/B/C |
17-5/32"
(436mm) |
20 |
6.4 |
10,000 |
| 05-0097A |
MIN-9A/B/C |
24-13/32"
(620mm) |
29 |
9.7 |
10,000 |
(1) Wattage is lamp watts only and does not include ballast loss (approximate).
(2) Maximum rated output at 254 nanometers.
The lamps listed above have been especially developed and are recommended for use with MINIPURE™ Water Purifiers.
All STER-L-RAY™ lamps used in MINIPURE™ units are low pressure type which afford the maximum efficiency in producing the required germicidal rays. In addition to the obvious advantages of high efficiency and low power requirements, there is no possibility of the unit overheating (as is the case with some other lamp types). Consequently, the need for additional equipment to combat overheating is eliminated.
CAUTION: Exposure to direct or reflected germicidal ultraviolet rays will cause painful eye irritation and reddening of the skin. Personnel subject to such exposure must wear suitable face shield, gloves and protective clothing. Hg - LAMP CONTAINS MERCURY, manage in accord with disposal laws, see: http://www.lamprecycle.org/
|
|
Bio-Logic® Ultraviolet Purifier Standard Model Germicidal Lamp Data
TO ORDER SELECT THE LAMP NUMBER FOR YOUR MODEL PURIFIER
|
| Lamp No. |
Model No. |
Nominal Lamp Length |
Power Consumption [Watts]
(1) |
UV Output [Watts] (2) |
Rated Effective Life [Hrs.] |
 |
| 05-1366 |
BIO-1.5A/B/C |
11-19/64"
(287mm) |
14 |
3.7 |
10,000 |
| 05-1370 |
BIO-3.0A/B/C |
17-5/32"
(436mm) |
20 |
6.4 |
10,000 |
|
(1) Wattage is lamp watts only and does not include ballast loss (approximate).
(2) Maximum rated output at 254 nanometers.
The lamps listed above have been especially developed and are recommended for use with Bio-Logic® Water Purifiers.
All STER-L-RAY™ lamps used in Bio-Logic® units are low pressure type which afford the maximum efficiency in producing the required germicidal rays. In addition to the obvious advantages of high efficiency and low power requirements, there is no possibility of the unit overheating (as is the case with some other lamp types). Consequently, the need for additional equipment to combat overheating is eliminated.
CAUTION: Exposure to direct or reflected germicidal ultraviolet rays will cause painful eye irritation and reddening of the skin. Personnel subject to such exposure must wear suitable face shield, gloves and protective clothing. Hg - LAMP CONTAINS MERCURY, manage in accord with disposal laws, see: http://www.lamprecycle.org/
|
|
Sanitron® Standard Models Germicidal Lamp Data
STER-L-RAY™germicidal lamps are shortwave, low pressure mercury vapor
discharge tubes that produce ultraviolet wavelengths lethal to microorganisms. |
| Lamp No. |
Model No. |
Nominal Lamp Length |
Power Consumption [Watts]
(1) |
UV Output [Watts] (2) |
Rated Effective Life [Hrs.] |
 |
| 05-1400 |
S14A/B/C |
8-15/16"
(227mm) |
10 |
2.3 |
10,000 |
| 05-1098 |
S17A/B/C |
11-7/8"
(302mm) |
14 |
3.7 |
10,000 |
| 05-1097 |
S23A/B/C |
17-3/4"
(451mm) |
20 |
6.4 |
10,000 |
| 05-1116 |
S37 |
31 1/4" |
38 |
13.8 |
10,000 |
|
|
(793mm) |
|
|
|
| 05-1343 |
S37A/B/C |
33-7/8"
(860mm) |
39 |
13.8 |
10,000 |
| 05-1334 |
S50A/B/C |
45-7/8"
(1165mm) |
50 |
19.3 |
10,000 |
| 05-1311(3) |
S2400A/B/C & larger |
46-1/4"
(1175mm) |
110 |
42 |
10,000 |
|
|
(1) Wattage is lamp watts only and does not include ballast loss (approximate).
(2) Maximum rated output at 254 nanometers.
(3) Patented by Atlantic Ultraviolet Corporation
The lamps listed above have been especially developed and are recommended for use with Sanitron® Water Purifiers. All STER-L-RAY™ lamps used in Sanitron® units are low pressure type which afford the maximum efficiency in producing the required germicidal rays. In addition to the obvious advantages of high efficiency and low power requirements, there is no possibility of the unit overheating (as is the case with some other lamp types). Consequently, the need for additional equipment to combat overheating is eliminated.
CAUTION: Exposure to direct or reflected germicidal ultraviolet rays will cause painful eye irritation and reddening of the skin. Personnel subject to such exposure must wear suitable face shield, gloves and protective clothing. Hg - LAMP CONTAINS MERCURY, manage in accord with disposal laws, see: http://www.lamprecycle.org/
|
|
|
For all prefilter needs for your purifier go to www.cleanfilterwater.com
 MUTIPLE UNIT ORDERS
ORDERS OF MORE THAN ONE PURIFIER E-MAIL US FIRST AT: hsb7hills@mac.com
 COMMERCIAL PURIFIERS AND REPLACEMENT PARTS
FOR YOUR COMMERCIAL AND REPLACEMENT NEEDS E-MAIL support@wateruvfilter.com
 Healthy Pet Beds
 As well as healthy water your pet needs a healthy bed. Go to www.petbeds4you.com
 Product Categories
To contact HSB MARKETING INC
Call 757-418-0817
Monday thru Friday 10:00 AM
To 4:00 PM EST
Or E-Mail at
hsb7hills@mac.com
 Shopping Basket
 Search by Keyword
Note: All prices in US Dollars
|
|