Commercial Sanitron S20000C (333GPM)
![]() |
| Click to enlarge image(s) |
PRICES DISCOUNTED
The water purifier's dual chamber heads are removable and may be rotated independently, which aids in the installation, maintenance or the retrofitting of an existing system. A drain port on the chamber head aids in the draining of the purifier.
• The water purifier's chamber, and chamber heads are electropolished and passivated type 316 stainless
steel.
• The ballast housing is type 304 stainless steel.
• Coated chambers are available for uses with special applications. Coated chambers are not recommended for use in drinking water applications or in applications where the treated product is consumed. Consult factory with your application requirements.
• The dual action wiper mechanism allows for quick and easy quartz sleeve cleaning, without interrupting service.
• EASY-OFF™ end caps allow for quick and easy lamp change, without disconnecting from the water supply or draining the purifier. No tools are required.
• Certain versions of 220v units have been designed to be CE compliant. These units have been tested to and comply with the requirements of the Electromagnetic Compatibility Directive and the Machinery Directive. The Declaration of Conformity lists the European Norm (EN) standards to which these units were tested, to demonstrate conformity
Flexibility - components are readily reconfigured to meet changing flow & process requirements
Independent Monitoring - single lamp chamber design enables output monitoring of each uv lamp
Standby Capacity - reserve chambers allows shutdown of components without service interrupt
Special Options - Protective Coating - for seawater & corrosive environments. Sanitary & Custom Fittings - for system compatibility. Special Configurations - for TOC and ozone reduction.
RECOMMENDED ACCESSORIES OPTIONS
SEE BELOW FOR LINK TO ACCESSORIES
1. Guardian™ Ultraviolet Monitor*: Visually indicates the level of germicidal ultraviolet energy that penetrates the quartz sleeve and the water within the water purifier. The ultraviolet monitor is capable of operating an optional audio alarm and/or solenoid valve. The ultraviolet monitor will detect reduction of ultraviolet levels due to:
• Fouling or deposits on the quartz sleeve.
• Poor ultraviolet transmission through the water; color, turbidity, and organic or other impurities in the water can reduce or interfere with the transmission of ultraviolet rays.
• Lamp outage, component or power failure.
• Depreciation of the lamp output due to usage or other cause. Lamp output gradually depreciates with use. Lamp replacement is recommended once each year.
2. Sentry™ Safety Sensor: Pilot lamps provide constant visual monitoring of normal operation. In the event of power or lamp failure the safety sensor indicates an alarm condition. The safety sensor is capable of operating an optional audio alarm and/or solenoid valve.
3. Steralert™: Lamp Status Alarm produces a high pitched, pulsed tone when the purifier is no longer functioning due to lamp or power failure.
4. SureFLO™: Flow Control Valve, limits water flow to the rated capacity of the purifier. The flow control valve is located in line prior to the water purifier, and should be protected from ultraviolet exposure by the use of a 90-degree elbow fitting between the flow control valve and the water purifier.
5. Audio Alarm*: Activated by the Ultraviolet Monitor or Safety Sensor, alerts the user to any malfunction detected.
6. Solenoid Valve*: Operated in conjunction with the Ultraviolet Monitor, Safety Sensor or Time Delay Mechanism, this valve prevents water flow through the water purifier when an abnormal condition is detected or in the event of power failure.
7. Elapsed Time Indicator: A non-resettable display of the water purifier operating hours. Useful for scheduling and recording maintenance and lamp replacement.
8. Time Delay Mechanism*: Provides a 2-minute warm up period during which the ultraviolet lamp achieves its full germicidal output before the water is allowed to flow through the water purifier. The time delay mechanism is used in conjunction with, and is electrically connected to the Solenoid Valve.
9. Mounting Stand supplied. Optimizes free air circulation to cool ballast housing.
*Use of this option is recommended by U.S. Public Health Service “Criteria for Acceptability of an Ultraviolet Disinfection Unit.” Originally issued April, 1966.
Optional Accessories Select Here
Replacement Lamps Select Here
Advantages:
Effective - virtually all microorganisms are susceptible to Sanitron™ ultraviolet disinfection.
Economical - hundreds of gallons are purified for each penny of operating cost.
Safe - no danger of overdosing, no addition of chemicals.
Fast - water is ready for use as soon as it leaves the purifier – no further contact time required.
Easy - simple installation and maintenance. Compact units require minimum space.
Automatic - provides continuous disinfection without special attention or measurement.
Chemical Free - no chlorine taste or corrosion problems.
Versatile - Capacities 333 gallons per minute.
Potable & high purity water applications
- 316 Stainless Steel, electropolished and passivated inside and out
- Easy Off™ Retainer Cap for effortless lamp change
- Drain Plug for in place drainage of the purifier
- Sight port to view germicidal lamp operation
- Removable flanged head for easy disassembly
- Patented dual action wiper mechanism for cleaning of the quartz sleeve
- Model S20,000C has heads that can be removed & rotated
- Protective Coating for seawater & corrosive environments available